Ortronics patch panel label template
Ortronics patch panel label template





  1. ORTRONICS PATCH PANEL LABEL TEMPLATE PATCH
  2. ORTRONICS PATCH PANEL LABEL TEMPLATE PLUS

ORTRONICS PATCH PANEL LABEL TEMPLATE PATCH

NCompass Category 6+ Cabling, Connectivity Hardware and Patch Cables shall be covered by a, nCompass Limited Lifetime warranty labor and application assurance warranty. Ortronics/Superior Essex nCompass Limited Life Time warranty for horizontal subsystem. IEEE 241 - IEEE Recommended Practice for Electric Power Systems in Commercial Buildings, pertaining to communication systems.

ortronics patch panel label template

NFPA 70 – National Electrical Code, current version adopted by local or State AHJ.ĪNSI/TIA/EIA 568-C – Commercial Building Telecommunications Cabling Standard, cur- rent version.ĪNSI/TIA/EIA 569-C – Commercial Building Standard for Telecommunications Pathways and Spaces, current version.ĪNSI/TIA/EIA 606-B – Administration Standard for Commercial Telecommunications Infra- structure, current version.ĪNSI/TIA/EIA 607-B – Commercial Building Grounding (Earthing) and Bonding Requirements for Telecommunications, current version. Work shall not proceed without OSU Information Services written approval of the submitted items.Īll work shall be performed in accordance with the following Codes and industry Standards, unless noted otherwise: Submit appropriate cut sheets and samples for all products, hardware and cabling as detailed in project specifications and drawings.

ortronics patch panel label template

Contractors must possess an Ortronics CIP and a Corning NPI certification within the state of Oregon to qualify for solicitation responses at the time an RFP is due for submission. It is the intent of Oregon State University's Campus Infrastructure Standard to ensure that a contractor is both an Ortronics CIP and a Corning NPI installer. The Telecommunications contractor is responsible for workmanship and installation practices in accordance with the Ortronics CIP Program and as the Corning Cabling Systems Program dictates. Solicitation responses will only be accepted from firms certified by Corning Cable Systems and Ortronics. Solicitation responses from a single contractor not certified by Ortronics and Corning Fiber Systems as (CIP/NPI) will not be accepted.

ORTRONICS PATCH PANEL LABEL TEMPLATE PLUS

The Telecommunications contractor submitting a response regarding an Oregon State University Voice/Data Infrastructure solicitation must be an approved Ortronics Certified Installer Plus (CIP) and a certified Corning Cabling Systems NPI Installer. This document shall be referenced within a projects specific scope of work. The contractor shall meet or exceed all requirements for any infrastructure system as detailed within this document. Quantities of telecommunications outlets, communication room details, equipment racks, cable routing and outlet types will be provided as project specific information by bid specification and/or bid drawings. Product specifications, general design considerations, and installation guidelines are provided in this document. The cables shall be installed from the Work Area Outlet to the appropriate Telecommunications Room (TR) and routed to the appropriate rack or backboard serving that area and terminated as specified in this document.Īll cables and related pathways, supports, terminations, and grounding hardware shall be furnished, installed, wired, tested, labeled, and documented by the Telecommunications contractor as detailed in this document and required by contract conditions. Category 6A will be required for all wireless access point horizontal cabling and research lab spaces. Category 3 cable will be required for conference room phones, classroom wall and emergency phones in addition to life safety connectivity (elevators, fire alarm, auto dialers). The Horizontal (workstation) Cabling System shall consist of a minimum of (2) Category 6, 4-pair Unshielded Twisted Pair (UTP) Copper Cables to each work area outlet within office locations unless otherwise noted for specific locations. All installations are warranted and shall be pre-registered with Ortronics/Superior Essex before work begins as does Corning Fiber systems. Backbone and horizontal cabling comprised of Copper and Fiber Optic, and support systems are covered under this document. This document describes general products and execution requirements relating to furnishing and installing Telecommunications Infrastructure consisting of communication rooms, spaces, power, pathways, and cabling for Oregon State University.

  • University Facilities, Infrastructure and Operations.
  • Procurement, Contracts & Materials Management.
  • Enterprise Project Portfolio Management Office.
  • ortronics patch panel label template

    University Administrative Business Center.Forestry, Oceanic and Atmospheric Business Center.Business and Engineering Business Center.Auxiliaries & Activities Business Center.Agricultural Sciences and Marine Sciences Business Center.